HP e3000 MPE/iX Release 7.0 System Software Maintenance Manual (30216-90317)
Appendix H 397
Error Messages and Warnings
Installer Error Messages (INSTERR)
Response Center for assistance.
137 Message BA-BI count mismatch. (INSTERR #137)
Cause Error while processing Binary patches.
Action Save PATCHAUD.INSTALL.SYS and contact the
Response Center for assistance.
138 Message 138 Not used
139 Message The installer could not find filename in
DLGINFO. (INSTERR #139)
Cause The installer could not find filename in the DLGINFO file.
This is typically caused by not purging the UNL.SYS,
USL.SYS or UXL.SYS groups on an UPDATE prior to
running the installer. Another possibility would be a
corrupt DLGINFO.PUB.SYS file.
Action If the USL, UXL, UNL groups were not purged prior to
starting the installation, purge them and restart the
installation procedures. If there is still a problem, contact
the Response Center for further assistance.
140 Message 140 Not used
141 Message The installer failed to STREAM SUPACCT. (INSTERR
#141)
Cause The installer received a nonzero return status when it
attempted to stream SUPACCT.
Action • Ensure there are no STREAM UDCs.
• Check the STREAMS and SPOOLER functionality by
streaming SUPACCT.INSTALL.SYS manually (note
that it should be a temporary file).
• Check the file SUPACCT.PUB.SYS for a valid JOB
card.
• Take appropriate corrective measures and run the
installer again.
• Contact the Response Center if further assistance is
required.
142 Message The installer was unable to build filename.
(INSTERR #142)
Cause The installer failed to build a permanent file using the
BUILD command.
Action • Check for free disk space to build file. There are two
methods for obtaining additional disk space:
• Use the ALTERVOL command in VOLUTIL to set the
permanent and transient space allocation assignments