HP e3000 MPE/iX Release 7.0 System Software Maintenance Manual (30216-90317)
Appendix H 391
Error Messages and Warnings
Installer Error Messages (INSTERR)
Action • The CREATEPROCESS intrinsic returned an error
status when attempting to execute
SAINT.MPEXL.SYS.
• Check the returned CREATEPROCESS error in the
MPE/iX Intrinsics Reference Manual.
• Print file AUTOLOG.INSTALL.SYS to check for
further errors.
• Perform corrective action for SAINT.
• Ensure ASAINTFL.INSTALL.SYS exists.
• Ensure group for SAINT has sufficient capabilities.
(need CAP=PH).
• Take appropriate corrective measures and run the
installer again.
• Contact the Response Center if further assistance is
required.
109 Message Error trying to RUN SYSGEN.PUB.SYS. (INSTERR
#109)
Cause Could not create SYSGEN process. Createprocess error:
status
• The CREATEPROCESS intrinsic returned an error
status when attempting to execute SYSGEN.PUB.SYS.
• Check the returned CREATEPROCESS error in the
MPE/iX Intrinsics Reference Manual.
• Print file AUTOLOG.INSTALL.SYS to check for
further errors.
• Perform corrective action for SYSGEN.
• Ensure ASYSGNFL.INSTALL.SYS exists.
• Ensure group for SYSGEN has sufficient capabilities.
(need CAP=PH).
• Take appropriate corrective measures and run the
installer again.
• Contact the Response Center if further assistance is
required.
110 Message Invalid product number prod_number. (INSTERR
#110)
Cause Either an invalid product number was entered manually,
or the local PRODLIST file contains an invalid entry.
Action • If entering data from the terminal during HPINSTAL,
run HPINSTAL again and enter the correct product
number.