HP e3000 MPE/iX Release 7.0 System Software Maintenance Manual (30216-90317)

Appendix H 373
Error Messages and Warnings
Installer Error Messages (INSTERR)
intrinsic patcher ABLDINTX.INSTALL.SYS failed.
Action FILE Command Table is possibly full.
Check if any further file commands can be entered with
the FILE command.
RESET any USER file equations.
Take appropriate corrective measures and run the
installer again. The installer will reissue any needed
file equations.
Contact the Response Center if further assistance is
required.
57 Message Error trying to RUN ABLDINTX.INSTALL.SYS.
(INSTERR #57)
Cause Could not create ABLDINTX process. Createprocess error:
status
Action The CREATEPROCESS intrinsic returned an error
status when attempting to execute
ABLDINTX.INSTALL.SYS.
Check the returned CREATEPROCESS error in the
MPE/iX Intrinsics Reference Manual.
Print file AUTOLOG.INSTALL.SYS to check for
further errors.
If ABLDINTX.INSTALL.SYS does not exist, restore
ABLDINTX.@.@ from the Powerpatch tape.
Ensure INSTALL group has sufficient capabilities.
(need CAP=PH).
Take appropriate corrective measures and run the
installer again.
Contact the Response Center if further assistance is
required.
58 Message Error trying to RUN BUILDINT.PUB.SYS. (INSTERR
#58)
Cause Could not create BUILDINT process. Createprocess error:
status
Action The CREATEPROCESS intrinsic returned an error
status when attempting to execute
BUILDINT.PUB.SYS.
Check the returned CREATEPROCESS error in the
MPE/iX Intrinsics Reference Manual.
Print file AUTOLOG.INSTALL.SYS to check for
further errors.