HP Smart Array Cluster Storage System
Hardware Options Installation
HP Smart Array Cluster Storage System User Guide 3-11
HP CONFIDENTIAL
Writer: Rob Weaver File Name: d-ch3 Hardware Options Installation
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/6/02 1:04 PM
Cache Upgrade Option
The controller ships with a 128-MB battery-backed cache module. A 256-MB
battery-backed cache module is available as an option. Before installing a cache
upgrade, observe the following guidelines:
• Always power down the system before performing a cache upgrade.
• If a controller has more than one cache DIMM, be sure that both DIMMs have
the same memory capacity.
• Always upgrade the cache in both controllers in a system with redundant
controllers.
• In a system with a redundant controller, be sure that both controllers have the
same number of DIMMs and that all DIMMs have the same memory capacity.
To upgrade the cache:
1. Power down the system. Refer to “System Power Down” in this chapter.
2. Remove the controller.
1
2
3