- HP Printer User Manual

Table Of Contents
ENWW Fuser 219
MFP disassembly/assembly
When reinstalling the
thermostat/U, adjust its
position using the
positioning tool
(00M8-1-00) and secure it
with screws. Be sure to
apply screw lock agent to
the screws. This
adjustment should be
made in a pressured state.
Removal procedure
1 Remove the fuser.
2 Remove the web cover.
3 Remove the cleaning web.
4 Remove one screw and two Faston
terminals to detach the thermostat/U.
Reinstallation procedure
1 Connect two Faston terminals to the
thermostat/U.
2 Set a thermostat positioning tool
(00M8-1-00) between the thermostat/U
and fusing upper roller and secure the
thermostat/U with one screw so that the
distance between the roller and
thermostat/U is equal to the thickness of
the tool.
3 Set the distance "a" between the
thermostat/U and fusing upper roller so
that it is equal to the thickness (B) of the
positioning tool.
Screw
Thermostat/U (TS1)
Faston terminals (2)
Thermostat/U
(TS1)
a
Fixing upper roller
Standard value of a: 3.75 0.25mm