User`s guide

10. To remove the magnetic roller, carefully lift the roller up
and out of the cartridge. Be very careful not to damage the
wire contact at the opposite end of the roller. It is not
necessary to remove the opposite end cap.
11. Remove the doctor blade by removing the two screws and
lifting it out straight up. When removing this blade, be very
careful not to break the alignment pins. These pins keep the
doctor blade at the proper distance from the magnetic roller.
12. Don’t damage or lose the clear plastic spacers, or the print
quality will suffer.
13. Vacuum the toner supply chamber thoroughly.
Fill the hopper with the appropriate amount of toner.
HP LASERJET 4100 TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS
© 2011 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only.
UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact techsupport@uninetimaging.com