Table 8 Business Continuity Manager error messages and corresponding troubleshooting actions
(message ID YKG2x YKK10x) (continued)
Explanation and recommended actionsMessage textMessage ID
Correct the specification on the line with the line number identified
by rec# in the file identified by file.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
A device address domain ID created by a remote scan or NG scan
is specified.
Specify the local DAD ID of
the primary site for the
DAD() parameter.
YKG286E MSG
SC=36 RC=36
(file:rec#)
Specify the local device address domain ID of the primary site in
the DAD parameter. For details about the NG scan, see the HP
XP7 for Business Continuity Manager Reference Guide.
file
Name of the XML file where the error was
detected
rec#
Number of the line where the error was detected
in the file identified by file
An attempt to acquire the variable vn failed with the result value
identified by result. This error can be caused by an invalid value
being specified for the STEM parameter.
YKVGET program failure for:
vn
YKG290E MSG
SC=44 RC=44
(result)
The internal routine encountered a shortage of work space.The element stack was
overflowed.
YKG295E MSG
SC=44 RC=44
(file:rec#)
Contact technical support for assistance.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
An unexpected error has occurred.YKGETHDA encountered an
unexpected error.
YKG298E MSG
TSO SC=44 RC=44
(detailed-info)
This error might have occurred with another error.
If another error message was output at the same time as this one,
follow the instructions in that message to fix the corresponding
problem.
If no other error message was output, collect the following materials
and contact your service representative:
The script from which this command was executed (not necessary
if this command was executed from the ISPF panel).
The ISPF log (not necessary if this command was executed from
a script).
The definition files operated on from the script or ISPF panel (the
copy group definition file, disk configuration definition file,
command device definition file and route list definition file).
detailed-info
Detailed information to assist service representative in resolving the
problem
46 Messages