Table 63 Details of error codes CBxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot
output
A CA copy pair cannot be
made because the necessary
CB68
difference area does not exist
in the MCU.
Not outputOutputNot outputThe upper limit of 4,096 (or
more) copy pairs cannot be
CB69
made within the same C/T
group by RCU.
Not outputOutputNot
output
A copy pair cannot be made
because the specified S-VOL is
defined as a command device.
CB78
Not outputOutputNot
output
A CA or CAA copy pair cannot
be made because the CLPR that
CB7E
the specified S-VOL belongs to
differs from the one registered
in the C/T group. For details
on the CLPR, see the storage
system documentation.
Not outputOutputNot
output
A copy pair cannot be made
because the specified S-VOL
CB9E
does not support either one or
both of the following:
The timestamp transfer
mode
The Open/MF Consistency
Preservation Function
Not outputOutputNot
output
A copy pair cannot be made
because the specified P-VOL is
not a P-VOL for CAJ.
CBD8
Not outputOutputNot
output
A copy pair cannot be created
because the specified S-VOL
CBD9
satisfies one of the following
conditions:
The S-VOL is being used for
FlashCopy.
The S-VOL is being used for
FlashCopy SE.
The S-VOL is a TSE-VOL.
Not outputOutputNot
output
A CA/CAA copy pair cannot
be made because the mirror ID
CBDC
of CAJ is 0 when linked with
CAJ.
Not outputOutputNot
output
A CA/CAA copy pair cannot
be made because a CAJ copy
CBDD
pair is being copied in a CAJ
Multi-Target configuration.
Not outputOutputNot
output
A copy pair cannot be created
because the specified P-VOL is
a pool volume.
CBE2
Details of error codes 237