HP XP7 Business Continuity Manager Messages (TK954-96003)

Table 50 Details of error codes 37xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputThe CAJ copy pair cannot be
created for the following
reasons:
3739
The CAJ copy pair is defined
with a different mirror ID.
The journal group that the
specified S-VOL belongs to is
not set to be used in a 3DC
(CAJxCAJ) configuration.
Not outputOutputNot outputThe specified CAJ copy pair
cannot be created in a 3DC
373D
(CAJxCAJ) configuration
because the S-VOL of the CAJ
copy pair is used in the
following program products:
CA
FCV2/FCSE
Auto LUN
THPz pool volume
Not outputOutputNot outputA CAJ copy pair cannot be
created between the primary site
373E
and the intermediate site in a
3DC Cascade (CAJxCAJ)
configuration because the mirror
status of the CAJ copy group
between the intermediate site
and the remote site is not
Initial or Stop.
Not outputOutputNot outputThe specified CAJ copy pair
cannot be created in a 3DC
3744
(CAJxCAJ) configuration
because the P-VOL of the CAJ
copy pair is in use by another
program product.
Not outputOutputNot outputA CAJ copy pair cannot be
created between the primary site
3745
and the intermediate site in a
3DC Cascade (CAJxCAJ)
configuration because the
specified M-JNL is not set to be
used in a 3DC (CAJxCAJ)
configuration.
Not outputOutputNot outputA CAJ copy pair cannot be
created with the HOLD
3753
parameter in a 3DC (CAJxCAJ)
configuration because the delta
resync function is not supported.
Details of error codes 187