HP XP7 Business Continuity Manager Installation Guide (TK954-96002)

1. SMPALLOC
Allocate the SMP/E control dataset as necessary. If an existing SMP/E control dataset is to
be used, skip this step.
For examples of modifying sample JCL (SMPALLOC), see “SMPALLOC (allocating SMP/E
datasets)” (page 89).
2. HPQYK1AL
Allocate the distribution library (DLIB) and the target library.
For examples of modifying sample JCL (HPQYK1AL), see “HPQYK1AL (allocating distribution
and target libraries)” (page 91).
3. HPQYK2DF
Execute SMP/E DDDEF to define the distribution library (DLIB) and target library.
For examples of modifying sample JCL (HPQYK2DF), see “HPQYK2DF (defining distribution
and target libraries)” (page 93).
4. HPQYK3RC
Execute SMP/E RECEIVE to load the provided datasets and store them in the global zone.
For examples of modifying sample JCL (HPQYK3RC), see “HPQYK3RC (SMP/E RECEIVE
processing)” (page 96).
5. HPQYK4AP
Execute SMP/E APPLY to install the provided dataset in the target library (the library shown
in “DASD storage attributes for target libraries” (page 15)).
The APPLY command in the sample JCL specifies the CHECK operand does not generate an
error, delete the CHECK operand and re-execute the job.
For examples of modifying sample JCL (HPQYK4AP), see “HPQYK4AP (creating target
libraries)” (page 98).
6. HPQYK5AC
Execute SMP/E ACCEPT to install the provided dataset in the distribution library (the library
shown in “DASD storage attributes for distribution libraries (DLIB)” (page 15)). The ACCEPT
command in the sample JCL specifies the CHECK operand. If execution with the CHECK operand
does not generate an error, delete the CHECK operand and re-execute the job.
For examples of modifying sample JCL (HPQYK5AC), see “HPQYK5AC (creating distribution
libraries)” (page 99).
NOTE: When the HPQYK4AP job executes successful, the new release of Business Continuity
Manager is installed. Verify that this new release of Business Continuity Manager executes correctly
and then accept it by executing the HPQYK5AC job.
Simple installation (installation without SMP/E)
This section explains installation that does not use SMP/E.
This method does not use SMP/E;, instead, installation is performed directly from the provided
dataset to the target library.
Members of the sample JCL library being installed must be changed according to the user's
installation environment. Details are shown at the beginning of each sample JCL. For modification
examples, see “Modifying sample JCL” (page 83).
Installing Business Continuity Manager 21