For details on how to use
ASM, refer to the
documentation for
Oracle RAC 11g.
#
You must apply MP3 or later.
Note
When a host and an Oracle RAC 11g voting disk are connected by
multiple paths, HDLM performs failover processing for those paths (in the
same way as for normal paths) when an I/O timeout occurs for one of the
paths.
Note that, depending on the settings of Oracle RAC 11g, Oracle RAC 10g
might determine that a node error has occurred before the failover
processing performed by HDLM is completed, and then re-configure the
cluster.
Therefore, when HDLM manages the paths that are connected to an
Oracle RAC 11g voting disk, change settings as described below.
¢
Change the value of MISSCOUNT to match the type of storage system.
To do so, use the following table to obtain the value to be specified,
and then change the current value to a value equal to or greater than
the value you have obtained.
Table 3-15 Formula for Calculating MISSCOUNT
Storage system type
Formula for obtaining the value of
MISSCOUNT
Lightning 9900V series
Hitachi USP series
Universal Storage
Platform V/VM series
Virtual Storage Platform
series
VSP G1000 series
HUS VM
number-of-paths-connected-to-the-voting-disk
x 60 seconds
Hitachi
AMS2000/AMS/WMS/SMS
series
HUS100 series
Thunder 9500V series
number-of-paths-connected-to-the-voting-disk
x 30 seconds
In addition to the value of MISSCOUNT shown above, also change the
value of DISKTIMEOUT. As with MISSCOUNT, the value to be specified in
DISKTIMEOUT is determined by the type of storage system. To make