HP StoreAll OS 6.5.1 Upgrade Guide

Steps for upgrading the firmware
IMPORTANT: On the StoreAll 9320 Storage platform the prerequisite measures must be followed
before performing the firmware update operation on enclosure hard disk drives:
Storage disk drive update is an OFFLINE process. Ensure that all host and array I/O must be
stopped prior to the update.
Make sure all the file systems are unmounted. Failure to comply may result in an OS crashing.
Ensure that no other user is performing administrative functions on the storage system.
Ensure that the storage system configuration is not being reconfigured during a firmware
update.
To avoid spurious failure indications and potential system crashes, you must suspend hardware
monitoring during the update process. You should execute hpspmonControl --pauseon
both servers in the couplet before performing the flash operation. You should then make sure
to execute hpspmonControl --resume on both servers in the couplet after the flash
operation is complete.
Do not cycle power or restart devices during a firmware update.
(9730 systems) Make sure the 69 (tftp) port is open before starting the firmware upgrade.
To upgrade the firmware for components:
1. First, run the FMT commands to determine what upgrades may be necessary:
On each server, execute hpsp_fmt -fr server.
On one server in the couplet, execute hpsp_fmt -fr storage.
(9730 and X9720 only) On the server identified as blade1, execute hpsp_fmt -fr
chassis.
52 Upgrading firmware