6.3 HP StoreAll 9300/9320 Storage Administrator Guide (AW549-96072, June 2013)

Manual upgrade
Check the following:
If the restore script fails, check /usr/local/ibrix/setup/logs/restore.log for
details.
If configuration restore fails, look at /usr/local/ibrix/autocfg/logs/appliance.log
to determine which feature restore failed. Look at the specific feature log file under /usr/
local/ibrix/setup/logs/ for more detailed information.
To retry the copy of configuration, use the following command:
/usr/local/ibrix/autocfg/bin/ibrixapp upgrade -f -s
Offline upgrade fails because iLO firmware is out of date
If the iLO2 firmware is out of date on a node, the auto_ibrixupgrade script will fail. The /usr/
local/ibrix/setup/logs/auto_ibrixupgrade.log reports the failure and describes how
to update the firmware.
After updating the firmware, run the following command on the node to complete the StoreAll
software upgrade:
/root/ibrix/ibrix/ibrixupgrade -f
Node is not registered with the cluster network
Nodes hosting the agile Fusion Manager must be registered with the cluster network. If the
ibrix_fm command reports that the IP address for a node is on the user network, you will need
to reassign the IP address to the cluster network. For example, the following commands report that
node ib51-101, which is hosting the active Fusion Manager, has an IP address on the user
network (192.168.51.101) instead of the cluster network.
[root@ib51-101 ibrix]# ibrix_fm -i
FusionServer: ib51-101 (active, quorum is running)
==================================================
[root@ib51-101 ibrix]# ibrix_fm -f
NAME IP ADDRESS
-------- ----------
ib51-101 192.168.51.101
ib51-102 10.10.51.102
1. If the node is hosting the active Fusion Manager, as in this example, stop the Fusion Manager
on that node:
[root@ib51-101 ibrix]# /etc/init.d/ibrix_fusionmanager stop
Stopping Fusion Manager Daemon [ OK ]
[root@ib51-101 ibrix]#
2. On the node now hosting the active Fusion Manager (ib51-102 in the example), unregister
node ib51-101:
[root@ib51-102 ~]# ibrix_fm -u ib51-101
Command succeeded!
3. On the node hosting the active Fusion Manager, register node ib51-101 and assign the
correct IP address:
[root@ib51-102 ~]# ibrix_fm -R ib51-101 -I 10.10.51.101
Command succeeded!
NOTE: When registering a Fusion Manager, be sure the hostname specified with -R matches
the hostname of the server.
The ibrix_fm commands now show that node ib51-101 has the correct IP address and node
ib51-102 is hosting the active Fusion Manager.
[root@ib51-102 ~]# ibrix_fm -f
NAME IP ADDRESS
-------- ----------
162 Cascading Upgrades