HP VMA-series Memory Array Installation and Service Guide

Chapter 5 - Operating the System via the CLI
92
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
Displaying and Setting Hardware Information
Display hardware information for the Memory Array, including:
Fan tray status
Which slots are populated with VIMMs
Individual VIMM information
•Test slots
•System LEDs
Displaying VIMM Configuration Information
Display the VIMM configuration information at the
Slot
context level.
To display the VIMM configuration information:
1. Log into the Memory Array.
2. Navigate to the desired
Slot
context level. At the root prompt, type:
Where:
3. At the context prompt, type:
This command displays text similar to the following:
context chassis board 0 slot <n>
n
Specifies the VIMM slot number to move to. Valid values are in
the range of 0–83, inclusive.
show vimm
chassis board 0 slot 56> show vimm
admin-state up
oper-state up
vimm-state active
raid-group 0
vimm-type FLASH
mem-type SLC-NAND
raw-capacity 68.7GB (64GiB)
raw-capacity-bytes 68,719,476,736
fmt-capacity 45.1GB (42GiB)
fmt-capacity-bytes 45,097,156,608
part-number 1000159A-B-P4
serial-number 18094R00000003
mfg-date 20090422
fw-date Thu Feb 11 17:54:00 2010
fw-version 0x39df