HP StorageWorks Ultrium Full-Height SCSI Tape Drives User Guide (EH853-90905, August 2007)

Please check your HP ProLiant server documentation to ascertain the correct method of mounting, and
to check whether mounting hardware is provided with the server.
Mounting rails
Some HP ProLiant servers, such as ML570, require m ounting rails. These may be metal or plastic rails
attached to the server’s drive bay ller panel.
Use a regular P
hillips screwdriver to attach the appropriate rails. Use the M3 screws provided with the
tape drive, in the screw pack labeled ’General Mounting Screws, as shown in Figure 5.
Figure 5 Attaching mounting rails in a typical HP ProLiant ML570
EnsureyoudousetheM3screwsprovided. Therailsmaybeattachedtotheller panel by screws of
a different thread/size type and these should not be used. If in doubt, refer to your HP ProLiant server
documenta
tion.
Mounting screws
Other HP ProLiant server models, such as ML350 and ML370, only require the use of special locating
screws with no mou nting rail.
Use a T8 Torx screwdriver to at tach the appropriate screws. You may need to purchase the M3 screws
separately. Position the screws, as shown in Figure 6.
HP ProLiant ML350: Use M3 mounting screws. These have a thicker head than the general
mounting screws.
HP ProLiant ML350: Use the metal shims and screw pack labeled ‘ProLiant 350’. These have a
thicker head than the general mounting screws.
HPProLiantML370: UseM3offsetmountingscrews. Thesehaveathickoffsetpieceanda
thicker head than the general mounting screws.
HP ProLiant ML370 : Use the metal shims and screw pack labeled ‘ProLiant 370’. These have a
thick offset piece and a thick er head than the general mounting screws.
24
Installing an internal tape drive