HP Surestore Tape Library User's Guide
210 Library Error Codes Appendix
Table 46 Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description Recovery Method
0 00H Error code not set.
■ Power cycle the library.
■ Observe the LEDs on the back of the library
controller card. See Interpreting Library LEDs
on page 130 to understand what the LEDs may
indicate.
1-8 01H -
08
H
Failed library
controller self test.
01h through 08h are controller tests. These errors
are possible only on power-up.
■ Power cycle the library.
■ Observe the LEDs on the back of the library
controller card. See Interpreting Library LEDs
on page 130 to understand what the LEDs may
indicate.
■ If failure persists, the library controller card
may be faulty.
9 09H Failed translate motor
test
.
Cannot translate the transport.
■ Check for a possible obstruction in the
transport pathway and remove it.
■ The umbilical cable may be faulty.
■ If the transport moves a little, but cannot fully
rotate around the assembly, a faulty motor is
indicated.
10 0AH Failed vertical motor
test
.
Occurs when trying to sense if the transport
assembly moves vertically. If the assembly does not
move:
■ Ensure that the motor leads are connected to
the vertical motor and the vertical lift board.
■ Check the umbilical cable under the translate
frame.