4 Powering on and managing the StoreOnce Management
system
In this chapter:
Powering on expansion shelves (page 28)
Powering on the HP StoreOnce Backup system (page 28)
Discovering the HP StoreOnce Backup system on the network (page 29)
Accessing the StoreOnce Management console (page 29)
User roles and accounts (page 30)
Password best practices (page 31)
Powering on expansion shelves, HP 4500 and 4700 only
If expansion shelves have been connected, ensure that any expansion shelves attached to the
system are powered on (1) before pressing the Power button on the head server units. You may
need to hold down the power on button (on the rear of each unit) for a few seconds.
IMPORTANT: HP StoreOnce 4700 only: The first storage enclosure must always be connected to
the correct RAID card in the head server unit before power on. If it connected incorrectly, the
Hardware tree in the StoreOnce GUI will display errors.
Figure 12 Powering on expansion shelves
Powering on the HP StoreOnce Backup system
Press the Power on button (1) on the front of your HP StoreOnce Backup system. The normal boot
sequence takes approximately 5 minutes. On power up the HP StoreOnce Backup system runs its
fans at high speed for approximately 10 seconds before returning to normal speed.
Figure 13 Powering on the HP StoreOnce 4700 Backup system