516 Configuring and monitoring FICON Extension Services
tape read pipelining.
-b 1|0 enables or disables FICON read block ID. 1 is enable, O is disable.
wrtMaxPipe value defines a maximum number of channel commands that may be outstanding at a
given time during write pipelining. Too small of a value will result in poor performance. The value
should be chosen carefully based upon the typical tape channel program that requires optimum
performance. The default value is 32. the range is 1-100.
rdMaxPipe value defines a maximum number of channel commands that may be outstanding at a
given time during read pipelining. Too small of a value will result in poor performance. The value
should be chosen carefully based upon the typical tape channel program that requires optimum
performance. The default value is 32. The range is 1-100.
wrtMaxDevs value defines a maximum number of concurrent emulated tape write operations. The
default value is 16. The range is 1-32.
rdMaxDevs value defines a maximum number of concurrent emulated tape read operations. The
default value is 16. The range is 1-32.
wrtTimer value defines a time limit for pipelined write chains. This value is be specified in
milliseconds (ms). If a pipelined write chain takes longer than this value to complete, the ending status
for the next write chain will be withheld from the channel. This limits processing to what the network
and device can support. Too small a value limits pipelining performance. Too large a value results in
too much data being accepted for one device on a path. The default value is 300 milliseconds (ms).
The range is 100-1500.
wrtMaxChains value defines the maximum amount of data that can be contained in a single CCW
chain. If this value is exceeded, emulation is suspended. The default is 3, which represents 3000000
bytes.
oxidBase value defines the base value of an entry pool of 256 OXIDs supplied to emulation
generated exchanges. It should fall outside the range used by FICON channels and devices to avoid
conflicts. The default value is 0x1000. The range is 0x0000 to 0xF000.
dbgFlags value defines optional debug flags. The default is 0xF7C80000. This is primarily for use
by technical support personnel.
The following example shows FICON emulation on ge1 over tunnel id 0 with FICON XRC, tape write
pipelining, tape read pipelining, TIN/TUR, and Device level ACK emulation enabled. The default values
are assumed for wrtMaxPipe, wrtMaxDev, wrtTimer, and wrtMaxChains. An oxidbase value of 0x7000 is
specified.
portcfg ficon ge1 0 config -x 1 -w 1 -r 1 -t 1 -l 1 oxidbase 0x7000