HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)

310 iSCSI gateway service
iSNS Client service:disabled
Enabling GbE ports
By default, GbE ports are enabled on an HP StorageWorks B-Series iSCSI Director Blade installed in the
HP StorageWorks 4/256 SAN Director. However, if you insert the HP StorageWorks B-Series iSCSI Director
Blade into a slot that was previously occupied by an FR-18i blade, GbE ports are disabled.
Before enabling the physical iSCSI interface, enable the iSCSI gateway service as described in ”Enabling
the iSCSI gateway service” on page 309.
NOTE: The GbE port number <port_number> below is entered geX; where X is numeral from 0 through 7.
For example ge1 (see Figure 39 on page 309).
1. Connect and log in to the switch.
2. Enter the portCfgShow command with the blade slot number and GbE port number parameters to
display the Persistent Disable setting of the port.
switch:admin> portcfgshow 10/ge0
Mode: ISCSI
Persistent Disable: ON
Ipif configuration:
Interface IP Address NetMask MTU
----------------------------------------------------------
0 30.0.130.100 255.255.0.0 1500
Arp configuration:
IP Address Mac Address
------------------------------
Iproute Configuration:
IP Address Mask Gateway Metric
------------------------------------------------------
switch:admin>
3. Take the appropriate action based on the Persistent Disable setting:
If it is set to OFF, proceed to step 4.
If it is set to ON, enter the portCfgPersistentEnable command with the slot number and
GbE port number.
switch:admin> portcfgpersistentenable 10/ge0
4. Enter the portCfgShow command with the slot number and GbE port number to verify that the port is
persistently enabled.
In the following sample output, the Persistent Disable setting is set to OFF.
switch:admin> portcfgshow 10/ge0
Mode: ISCSI
Persistent Disable: OFF
Ipif configuration:
Interface IP Address NetMask MTU
----------------------------------------------------------
0 30.0.130.100 255.255.0.0 1500