HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 10.3.4 Release Notes (5697-0436, April 2010 - includes all 10.3.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Re-launch the client, and then launch
the Connection Properties dialog for
the tunnel.
DCFM does not display newly configured tunnels. This makes it difficult
to determine if the connection between tunnels for specific ports was
successful.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Re-launch the client, and then launch
the Connection Properties dialog for
the tunnel.
DCFM display is not updated after deleting multiple tunnels. This makes
it difficult to determine if the delete operation was successful.
Fixed in DCFM 10.3.0
The FCIP Tunnel Setup wizard panics when trying to set up tunnels on
GE1 on an HP StorageWorks Multiprotocol Router Blade.
Fixed in DCFM 10.3.0
The Zoning Save To dialog should only show the zones that are being
changed. Currently, this dialog is ambiguous.
Fixed in DCFM 10.3.0
Not all tunnel information is displayed in the IP Properties window
because of a missing scroll bar.
Fixed in DCFM 10.3.0
IP tunnel information is repeated for the bandwidth unit in Connection
Properties > Selected Connection Properties.
Fixed in DCFM 10.3.0
Clicking OK or Apply after configuring a TI zone activates the new
zoning information. Users want to be able to save zoning information
without activating it.
Fixed in DCFM 10.3.0
If you attempt to configure tunnels in a FICON environment with VLANs
and VEX ports, there is no warning message to inform you that this
configuration is not supported in FICON.
Fixed in DCFM 10.3.0You cannot view the DCFM Master Log until after you restart the client.
Fixed in DCFM 10.3.0
The Active Zone Config Report displays inaccurate Active TI Zone in-
formation.
Fixed in DCFM 10.3.0
An attempt to generate a report from the Zone DB tab generates an
Active Zone Config Report instead of the expected Zone DB summary.
Fixed in DCFM 10.3.0
The Setup FICON Display in Options dialog is not working for the
Device Tree table, FC Port Connectivity View, and Trace Route dialog.
When changes are made in the product list, the Options dialog does
not change the column order.
Fixed in DCFM 10.3.0DCFM does not display configured M-EOS switch names.
Fixed in DCFM 10.3.0
If you attempt to replace Encryption Engine (EE) functionality on an
encryption switch or encryption blade that has different media types
(tape and disk), an EE is offline error message is displayed in-
stead of a message that states that the operation is not supported
between EEs of different media types.
Fixed in DCFM 10.3.0LUN size is displayed in KB instead of MB in the Encryption dialog.
Fixed in DCFM 10.3.0
If you change the LUN configuration with encryption switches, you
must re-enter the LUN information.