HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.As a result of a switch going unreachable, HA Failover
was performed from Slot6 to Slot7. Slot7 then experienced
a panic, rebooted, and an outage occurred.
Fixed in Fabric OS 7.1.0.Access Gateway does not clean up frame exchange
properly if FLOGI/FDISC comes in from different ports
together with same exchange ID (OX-ID).
Workaround prior to upgrade:After power cycling an HP SN8000B SAN Director, the
HP SN8000B 16Gb 32-port Fibre Channel Blade is set to
Faulty-51.
Power cycle the blade or the chassis.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The Topologyshow command is not correct on the HP
2408 FCoE Convergerd Network Switch with Port-based
routing.
Fabric OS 7.1.0a fixes
Table 10 (page 63) lists defects closed in the Fabric OS 7.1.0 firmware release.
Table 10 Fabric OS 7.1.0a closed defects
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0a.CRC with good EOF errors detected on the HP DC SAN
Backbone Director with an HP SAN Director 48-port 8Gb
FC Blade insertd in slot 3 on ports 3/42 <-> 8/139.
Fixed in Fabric OS 7.1.0a.On an HP DC04 SAN Director, backend CRC errors are
detected on core blade ports 3/56 connecting the HP SAN
Director 32-port 8Gb FC Blade.
Workaround prior to upgrade:The Error log content is being cleared of prior messages
when migrating to Fabric OS 7.1.0.
Supportsave can be used to save and retain the error
log contents if the supportsave is successfully executed
prior to the firmwaredownload upgrade to Fabric OS
7.1.0.
Fixed in Fabric OS 7.1.0a.
Fabric OS 7.1.0b fixes
Table 11 (page 63) lists defects closed in the Fabric OS 7.1.0 firmware release.
Table 11 Fabric OS 7.1.0b closed defects
SolutionClosed defect summary
Workaround prior to upgrade: Disable FCIP OSTP
emulation or limit tunnel bandwidth to less than 5 Gb with
fewer than 5 FCIP circuits.
FCIP OSTP tape backup job fails with File too large
errors when running to a new tape device.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.The RASLog error message C2-5825 Detect CRC error
with good EOF is displayed on an HP DC04 SAN
Director core blade port 3/56 with an HP SAN Director
32-port 8Gb FC Blade installed.
Fixed in Fabric OS 7.1.0b.Unstable ICL/BI ports may cause a switch panic/reboot
on an HP DC SAN Backbone Director with an HP DC SAN
Director Multiprotocol Extension Blade installed.
Fabric OS 7.1.0a fixes 63