HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.There is a potential inability for FICON channels to
successfully establish logical paths to the CUP in
configurations where there is a large number of
sub-channels defined to the CUP.
Fixed in Fabric OS 7.1.0.Ports without errors are fenced during supportsave.
Fixed in Fabric OS 7.1.0.Infrequently, LUN discovery failure may be encountered
after HAC failback for certain tape devices.
Fixed in Fabric OS 7.1.0.In a FICON environment (without CUP) inconsistent
switchshow output displays on Port #254 and #255 as
port 254 is showing "Disabled (FMS Mode)" and port 255
is showing "Disabled (Persistent) (FMS Mode)”.
Workaround prior to upgrade:When users set up the ADS policy from NO ACCESS to
ALL ACCESS on an FCoE switch, if an NPIV device logs
in, the respective port may be disabled.
Execute the command fcoe --disable <portnum>
and fcoe enable <portnum>
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:If LSAN Binding is added to an FCR configuration with
Speed Tags already defined, binding may not be properly
Remove the stale configuration.
enforced and devices may not be properly
imported/exported.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.If a tape device is improperly identified as a disk device,
the HP Encryption SAN Switch may hang and go faulty.
Fixed in Fabric OS 7.1.0.Disabling or shutting down an HP Encryption SAN Switch
may cause third-party storage to go offline.
Fixed in Fabric OS 7.1.0.Devices may be unable to communicate with peer devices
after a logout/login sequence.
Fixed in Fabric OS 7.1.0.RASlog severity level for AN-1003 raised from WARNING
to ERROR in Fabric OS 6.3.2c and later releases, providing
an easier interface for SNMP traps. Users who do not want
to see this RASlog should leave Bottleneck Detection
disabled.
Fixed in Fabric OS 7.1.0.While inserting an HP DC SAN Director Mutliprotocol
Extension Blade in the SN8000B Directors, there are verify
errors for the ports with invalid speed configurations. The
ports will be disabled persistently.
Fixed in Fabric OS 7.1.0.There are delays detected in Name Server during FICON
CEC IMLs.
Fixed in Fabric OS 7.1.0.Web Tools zoning window fails to launch if device Port
WWN and Node WWN are the same.
Workaround prior to upgrade:FIPS mode with DSA keys are allowed, but should be a
blocked scenario.
CLI(s) to configure FIPS certified configuration for Mgmt IP
Sec, FCIP IP Sec, SSH public key authentication should be
executed for complete FIPS compliance.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Unable to make modifications on the Canvas Configuration
List of WebTools (SID/DID Performance).
Fixed in Fabric OS 7.1.0.Continuous HA Failover on an HP DC SAN Backbone
Director may lead to an FFDC event.
Fixed in Fabric OS 7.1.0.A 4 Gb/s switch failed to go active due to ASIC
initialization failure.
Fabric OS 7.1.0 fixes 43