Brocade Fabric OS Command Reference Manual v6.2.0 (53-1001186-01, April 2009)

174 Fabric OS Command Reference
53-1001186-01
diagSetCycle
2
diagSetCycle
Sets diagnostic script parameters.
Synopsis diagsetcycle [ script | -current [-show | -default | -keyword value ..]]
Description Use this command to update diagnostic command parameters. If only a script is specified, the
command displays all configuration variables used by the specified script and enters an interactive
session. Using the full parameters, variables can be updated non-interactively.
In interactive mode, the current value, default value, and description of purpose of the variable are
displayed for each variable. If no new value is specified, the current value is left unchanged. If a
new value is entered, its value is updated and stored in the configuration database for that blade
type. This command does not require a reboot to take effect.
It is recommended to run the burninErrClear command prior to running diagSetCycle.
Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands This command has the following operands:
script Specifies the script for which you want to change parameters.
-current Specifies the current script.
-show Displays the parameters for the specified diagnostic script.
-default Sets the script parameters to default values.
-keyword value Updates the script parameters non-interactively. The specified value is the
keyword to update.
Examples To display diagnostic command parameters:
switch:admin> diagsetcycle switchburnin.sh -show
CURRENT - KEYWORD : DEFAULT
1 - number_of_runs : 1
2 - vib : 2
10 - thermal : 10
BURNIN - label : BURNIN
1 - tbr_passes : 1
1 - prt_on : 1
1 - cntmem_on : 1
1 - cmi_on : 1
1 - retention_on : 1
1 - cam_on : 1
50 - flt_passes : 50
25 - sta_passes : 25
100 - plb_nframes : 100
50 - txd_nframes : 50
200 - xpt_nframes : 200
20 - bpt_nframes : 20
50 - slk_nmegs : 50
[output truncated]
See Also burninLevel