Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 545
53-1000599-02
portTrunkArea
2
Examples To enable masterless F_Port trunking on a standalone switch:
1. Disable ports 36 - 39 by executing portdisable port for each port to be included in the TA.
2. Enable Trunk Area for ports 36 - 39 with area number 37:
switch:admin> porttrunkarea --enable 36-39 -area 37
Trunk area 37 enabled for ports 36, 37, 38 and 39.
3. Re-enable ports 36-39 by executing portenable port for each port in the TA.
4. Show switch/port information:
switch:admin> switchshow
switchName: SPIRIT_B4_01
switchType: 66.1
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 2
switchId: fffc02
switchWwn: 10:00:00:05:1e:41:22:80
zoning: OFF
switchBeacon: OFF
FC Router: ON
FC Router BB Fabric ID: 100
Area Port Media Speed State Proto
=====================================
0 0 -- N8 No_Module
1 1 -- N8 No_Module
2 2 -- N8 No_Module
3 3 -- N8 No_Module
4 4 -- N8 No_Module
5 5 -- N8 No_Module
6 6 -- N8 No_Module
7 7 -- N8 No_Module
8 8 id N4 Online F-Port 10:00:00:00:00:01:00:00
9 9 -- N8 No_Module
10 10 -- N8 No_Module
11 11 -- N8 No_Module
12 12 -- N8 No_Module
13 13 -- N8 No_Module
14 14 -- N8 No_Module
15 15 -- N8 No_Module
16 16 -- N8 No_Module
17 17 -- N8 No_Module
18 18 -- N8 No_Module
19 19 -- N8 No_Module
20 20 -- N8 No_Module
21 21 -- N8 No_Module
22 22 -- N8 No_Module
23 23 -- N8 No_Module
24 24 -- N8 No_Module
25 25 -- N8 No_Module
26 26 -- N8 No_Module
27 27 -- N8 No_Module
28 28 -- N8 No_Module
29 29 -- N8 No_Module
30 30 -- N8 No_Module
31 31 -- N8 No_Module