Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 309
53-1000599-02
iscsiPortCfg
2
--show Displays port-level protocol parameters, statistics, and session information
on the specified port. Options include:
-v Specifies verbose mode, which displays the initiator IP, TSID, and the number
of connections in addition to the other port-level information.
slot Specifies the slot number. This parameter only supports FC4-16IP blades in
Brocade 48000 directors.
geport Specifies the port number of a GbE port to be configured in the specified slot.
-h Use -h on any option to display the help text for it.
Examples To modify the port parameters:
switch:admin> iscsiportcfg --modify 7/ge2 -e 2 -c 2 -f 32768
The operation completed successfully.
To display the port information in verbose mode:
switch:admin> iscsiportcfg --show 7/ge0
The configured port parameters for slot 7 and port ge0 are:
Header Digest: Off
Data Digest: Off
First Burst Length: 512
Error Recovery Level: 0
Immediate Data: Off
Connections per session: 1
Num. of active sessions on port: 1
Port Statistics:
iSCSI in PDU: 211
iSCSI in Octet: 32592
iSCSI out PDU: 307
iSCSI out Octet: 77484
FCP in PDU: 205
FCP in Octet: 76356
FCP out PDU: 114
FCP out Octet: 29944
iSCSI Command: 104
iSCSI R2T: 11
iSCSI Data In: 11
iSCSI Data Out: 96
iSCSI Response: 104
FCP Command: 103
FC Data In: 91
FC Data Out: 11
FC XFer Ready: 11
FC Response: 103
iSCSI Error PDU: 0
FC Error PDU: 0
iSCSI Snack: 0
iSCSI NOP Out: 0
iSCSI Text: 1
iSCSI Logout: 1
iSCSI Task Mgmt.: 0
iSCSI TM Response: 0
iSCSI Abort Task: 0