HP X5000 G2 Network Storage System Administrator Guide
Replacing the server airflow baffle
1. Install the replacement server blade airflow baffle (Figure 76 (page 85)).
Figure 76 Installing the server blade airflow baffle
2. Reinstall the top back panel.
3. Replace the enclosure as described in “Inserting the system enclosure into the rack” (page 68).
Removing and replacing the front bezel (standard)
NOTE: Use “Removing and replacing the front bezel (full)” (page 87) if you are not able to reach
all of the screws due to the position of the system in the rack.
Removing the front bezel
1. Power off the system as described in “Powering the storage system off and on” (page 60).
2. Extend the hard drive drawer (Figure 77 (page 85)):
a. Press upward on the release button on the hard drive drawer (1).
b. Pull the drawer handle down 90 degrees (2).
c. Extend the hard drive drawer (3).
Figure 77 Extending the hard drive drawer
Removing and replacing the front bezel (standard) 85