HP X5000 G2 Network Storage System Administrator Guide
Replacing the fan module
1. Insert the replacement fan module (Figure 60 (page 76)).
Figure 60 Replacing the fan module
2. Verify that the replacement component is working properly by checking the associated LED
status.
NOTE: It should take approximately 15 seconds for the LED status to appear.
3. Confirm that the system has resumed normal operations.
Removing and replacing the power UID button assembly
Removing the power UID button assembly
1. Power off the system as described in “Powering the storage system off and on” (page 60).
2. Remove the enclosure from the rack as described in “Removing the system enclosure from the
rack” (page 67).
3. Remove the top back panel by pressing the panel release button and lifting the latch to slide
the top back panel off.
4. Remove the hard drive fan module (Figure 61 (page 76)).
Figure 61 Removing the fan module
76 Removing and replacing hardware components