3.02.2a HP StoreEasy Storage Release Notes (B7E02-96054, October 2013)
NOTE:
• You must be logged in as the local administrator to install the service release.
• On systems that have no internet access, the service release installer may pause for up to five
minutes while displaying the message, “Please wait while we scan your system for applicable
software.” This is due to PowerShell scripts, signed by HP, that are being used to scan for software
to be updated. With no internet access, certificate revocation lists cannot be checked, but there
is a delay before the check fails and allows the script to continue. Wait for the scan to complete
and then the service release installation will continue.
• The service release executable must be run at least twice on each server blade and requires a
firmware upgrade for applicable hardware components during the installation process. Some
hardware components cannot be upgraded until a particular component is upgraded first. The
service release installation window that displays includes instructions to follow. You can also refer
to the HP StoreEasy 5000 Storage Administrator Guide for firmware upgrade procedures.
1. Download the service release file:
a. Go to http://www.hp.com/go/support.
b. Select Drivers and Software.
c. Enter your product (for example, StoreEasy 5000) in the Enter a product name/number box
and click Search.
d. Select your model, select the operating system, and then select the service release.
e. Copy ServiceRelease_swx_3.02.2a.exe to a temporary folder on your system.
2. If the system is a cluster, complete the following steps to ensure the file system is not affected:
a. Select Server Manager→Tools→Failover Cluster Manager.
b. Select the cluster. Expand the navigation tree for the cluster if it is not already expanded.
c. Expand Services and applications and then select the clustered file server service.
d. Under Action, select Move this service or application to other node.
Confirm your selection on the confirmation window that is displayed.
e. Repeat these steps for each file server.
3. Run ServiceRelease_swx_3.02.2a.exe on the server blade in Bay 1 and follow the prompts
on the service release installation window. Run the service release installer until all required
components have been installed.
NOTE:
• If you launch more than one instance of the executable, an incorrect error message is
displayed. Instead of indicating that another instance is running, the following error message
is displayed:
7 zip, internal error, code 105
• When you are prompted to reboot during the installation, the "Installation is complete"
message displays in the installer window with two checkboxes—Cleanup and Reboot (both
selected by default). Because more than one reboot is required during installation, HP
recommends that you uncheck the Cleanup box until you have finished the installation. If you
forget to run the cleanup, you can run the service release installer again. The installer returns
to the point in the process where you previously stopped.
4. Copy ServiceRelease_swx_3.02.2a.exe from the server blade in Bay 1 to the server blade
in Bay 2 and repeat steps 2 and 3 on that server blade.
10 Installation instructions (existing 5000 storage systems)