HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)

25 Volume Shredder (SHRED) function
End Shredding operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[SHRED],End Shredding,,Normal end,Seq.=xxxxx
+{Times,Result}=[{1,Nomal},{2,Nomal},{3,Error}],Num. of Data=3
[SHRED]
SHRED function
End Shredding
End Shredding operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 177 Detailed information for End Shredding operation
DescriptionItem
The execution sequence (1 to 8) of shredding operations.Times
The result of the shredding opration.
Normal: Normal end, Failed: Abnormal end, Canceled: Canceled, Not executed:
Not executed, Data transfer error: File output error of the result, Data verify error:
Verify error
Result
The number of shredding opereations.Num. of Data
Set Shredding operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[SHRED],Set Shredding,,Normal end,Seq.=xxxxx
+OwnerID=0
+{Data,Output File}={0xffff,Disable},{Random,Disable},{0x00,Enable},Num. of Data=3
+{Output LDEV}={0x00:0x00,0x00:0x01,0x00:0x02},Num. of LDEVs=3
+{Shred LDEV}=
{0x00:0x00,0x00:0x01,0x00:0x02,0x01:0x00,0x01:0x01,0x01:0x02,0x03:0x00,0x03:0x01,0x03:0x02,
0x0a:0xa0,0x0a:0xa1,0x0a:0xa2,0x0a:0xa3,
-0x1f:0xf8,0x1f:0xf9,0x1f:0xfa,0x1f:0xfb,0x1f:0xfc,0x1f:0xfd,0x1f:0xfe,0x1f:0xff},
Num. of LDEVs=21
[SHRED]
XP Audit Log reference guide 195