4. If there are empty bays, insert a blanking plate. This is essential to ensure adequate airow is
maintained. Failure to do so may affect tape drive performance.
See the documentation with the tape array for details on installing blanking plates.
Set the drive’s SCSI ID
To set the
tape drive’ s SCSI ID you need to set the appropriate switch on the rear of the tape array. The
number of address switches corresponds to the number of tape drives that can be inserted into the
tape array.
Each devi
ce on the SCSI bus must have a unique SCSI ID.
For HP P roLiant ser vers where the tape drive is connected to the built-in SCSI bus, we recommend
that the tape drive is assigned a SCSI ID between 1 and 6.
For all o
ther servers and when used with separate HBAs, it can be assigned any unused ID
between
0 and 15. D o not use SCSI ID 7, which is reserved for the SCSI controller. SCSI ID 0
is typically assigned to the boot disk and should also not be used unless the tape drive is on a
dedicated SCSI bus.
Typical
ly, the HP Tape Array may hold up to four tape drives where each drive is attached to a separate
server. Under this conguration, the SCSI IDs of each tape drive will not conict with each other as they
are each installed onto a separate SCSI bus. This is the recommended conguration for Ultra320 devices,
such as the Ultrium 1840 and Ultrium 9 60 tape drives.
If you d
aisy-chain devices make sure that the devices are of the same SCSI type and that each device on
the same SCSI bus has a unique SCSI ID. Do not daisy-chain more than two devices on the same SCSI
bus and make sure that the end device is terminated. Do not mix drive families (only daisy-chain with
other
Ultrium tape drives) and do not put Ultra160 drives on the same bus as any Ultra320 device.
1. Decide which SCSI ID to use.
For many operating systems you can install HP Library & Tape Tools from the HP StorageWorks Tape
CD-ROM and run the “Install Check to check your com puter’s current SCSI conguration (see
Diagnostic tools ). This will provide information about the SCSI bus and the SCSI IDs in use. The
UNIX Conguration Guide on the HP StorageWorks Tape CD-ROM, also provides instructions on
how to determine the SCSI I Ds of existing devices.
2. Set the appropriate switch. Figure 16 shows the add ress switch on the back panel of the
HP T
ape Array 5300.