HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 271
Recommended Action
Install the missing fan FRUs immediately.
Severity
WARNING
HIL-1404
Message
Probable Cause
Indicates that one or more fan FRUs have been removed.
Recommended Action
Install the missing fan FRUs immediately.
Severity
WARNING
HIL-1501
Message
Probable Cause
Indicates that the temperature of this blade has risen above the warning threshold. This message only
occurs on the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
Run the tempShow command to monitor switch temperatures. Refer to the hardware reference manual for
the temperature range of your switch.
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well ventilated and that the room temperature is within operational range of
your switch. Refer to the hardware reference manual for your switch for the operational temperature range.
Severity
WARNING
HIL-1502
Message
<timestamp>, [HIL-1404], <sequence-number>,, WARNING,
<system-name>, <count> fan FRU(s) missing. Install fan FRU(s)
immediately.
<timestamp>, [HIL-1501], <sequence-number>,, WARNING,
<system-name>, Slot <slot number>, high temperature (<measured
temperature>).
<timestamp>, [HIL-1502], <sequence-number>,, CRITICAL,
<system-name>, Slot <slot number>, high temperature (<measured
temperature>). Unit will be shut down in 2 minutes if temperature
remains high.