HIL-1301
Message
Probable Cause
Indicates that a fan FRU has failed. This message is often preceded by a low speed error message. This
problem can quickly cause the switch to overheat.
Recommended Action
Run the tempShow command to check if the switch temperatures are too high. Refer to the hardware
reference manual for the temperature range of your switch.
Run the fanShow command to verify that the fan is faulty.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the fan FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, Brocade 4Gb SAN Switch for HP p-Class Blade, SAN Switch
2/8V and SAN Switch 2/16V, the entire switch must be replaced, because these switches do not have
FRUs.
Severity
ERROR
HIL-1302
Message
Probable Cause
Indicates that multiple fan FRUs have failed on a switch. This message is often preceded by a low fan
speed message.
Recommended Action
Run the tempShow command to check if the switch temperatures are too high. Refer to the hardware
reference manual for the temperature range of your switch.
Run the fanShow command to verify that the fans are faulty.
For the SAN Switch 2/32 and SAN Switch 4/32, replace the fan FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
Severity
ERROR
<timestamp>, [HIL-1301], <sequence-number>,, ERROR, <system-name>,
1 blower failed. Replace failed blower assembly immediately.
<timestamp>, [HIL-1302], <sequence-number>,, ERROR, <system-name>,
<count> blowers failed. Replace failed blower assemblies
immediately.