HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
236 Error messages
Recommended Action
Responses to security-class messages depend on user policies. Consult your security administrator for
response strategies and policies.
Severity
INFO
FW-1349
Message
Probable Cause
Indicates that the number of invalid signatures has fallen below the low boundary. Invalid-signature
violations indicate that a packet with an invalid signature has been received from the primary FCS. When
the primary fabric configuration server (FCS) downloads a new configuration to the other switches in the
fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this
signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This
counter keeps track of the number of packets received with invalid signatures.
Recommended Action
No action is required.
Severity
INFO
FW-1350
Message
Probable Cause
Indicates that the number of invalid signatures has risen above the high boundary. Invalid-signature
violations indicate that a packet with an invalid signature has been received from the primary FCS. When
the primary fabric configuration server (FCS) downloads a new configuration to the other switches in the
fabric, the packet is signed using the private key of the primary FCS. The receiving switch has to verify this
signature with the public key of the primary FCS switch. If verification fails, it rejects the packet. This
counter keeps track of the number of packets received with invalid signatures.
Recommended Action
Responses to security-class messages depend on user policies. Consult your security administrator for
response strategies and policies.
Severity
WARNING
<timestamp>, [FW-1349], <sequence-number>,, INFO, <system-name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
<timestamp>, [FW-1350], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.