HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 169
Probable Cause
Indicates that an application has sent too many concurrent high availability (HA) data updates.
Recommended Action
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system. The haSyncStart command will automatically run the haSyncStop command if required.
If the message persists, run supportFtp and traceFtp -e (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1003
Message
Probable Cause
Indicates that the FSS has dropped the update because an application has not set the transaction flag
correctly.
Recommended Action
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system. The haSyncStart command will automatically run the haSyncStop command if required.
If the message persists, run supportFtp and traceFtp -e (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1004
Message
Probable Cause
Indicates that the system ran out of memory.
Recommended Action
Run the memShow command to view memory usage.
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system. The haSyncStart command will automatically run the haSyncStop command if required.
If the message persists, run supportFtp and traceFtp -e (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.
Severity
ERROR
<timestamp>, [FSS-1003], <sequence-number>,, WARNING,
<system-name>, Application missing first HA data update
<timestamp>, [FSS-1004], <sequence-number>,, ERROR, <system-name>,
Memory shortage