HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

Fabric OS 5.x diagnostics and system error messages reference guide 139
Severity
WARNING
EM-1058
Message
Probable Cause
Indicates the switch is getting an automatic reset. This is usually a transient problem.
Recommended Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
EM-1059
Message
Probable Cause
Indicates that a FRU inserted in the specified slot is not compatviel with the switch sofware. The blade is
faulted. This message only occurs on the Core Switch 2/64, SAN Director 2/128, or 4/256 SAN
Director.
Recommended Action
Replace the blade. Verify that the replacement blade is compatible with your CP types and your
chassisConfig option.
Severity
CRITICAL
EVMD error messages
EVMD-1001
Message
Probable Cause
The TCP socket is closed because of a TCP write error. There can be many causes for this loss of
connection:
The API host application exits without notifying the switch.
<timestamp>, [EM-1058], <sequence-number>,, WARNING, <system-name>, Switch gets
reset: <fault reason>
<timestamp>, [EM-1059], <sequence-number>,, CRITICAL, <system-name>, Incompatible unit
in <FRU Id> faulted
<timestamp>, [EVMD-1001], <sequence-number>,, WARNING,
<system-name>, Event session killed, host IP = <Host IP address>,
port = <Host TCP port number>