HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

130 Error messages
Recommended Action
Check that the identified AC circuit switch is turned on, that the power cord is properly attached and
undamaged, and that the power source is operating properly.
Severity
ERROR
EM-1036
Message
Probable Cause
Indicates that the specified FRU does not seem to be present on the switch.
If the FRU is a WWN card, then default WWN and IP addresses are used for the switch.
Recommended Action
Reseat the FRU card.
If the message persists, reboot or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems. Refer
to the
HP StorageWorks Fabric OS 5.x command reference guide
for more information on this command.
If the message persists, replace the FRU.
Severity
WARNING
EM-1041
Message
Probable Cause
Indicates that sensors detected a warning condition. All significant sensors for the FRU are displayed; each
contains a header.
The FRU ID value is composed of a FRU type string and an optional number to identify the unit, slot, or
port. The FRU ID value can be:
Switch for fixed port count switches.
Slot 1 through Slot 10 for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
PS 1 through PS 4 (power supplies) for the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN
Director, or PS 1 through PS 2 for the SAN Switch 2/32 and SAN Switch 4/32. The power supplies on
the SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
Fan 1 through Fan 3 for the Core Switch 2/64, SAN Director 2/128, and SAN Switch 4/32 (six fans
in three FRUs). Fan 1 through Fan 6 for the SAN Switch 2/32 (six fans in three FRUs). The fans on the
SAN Switch 2/8V and the SAN Switch 2/16V are not field replaceable.
<timestamp>, [EM-1036], <sequence-number>,, WARNING, <system-name>,
<FRU Id> is not accessible.
<timestamp>, [EM-1041], <sequence-number>,, WARNING, <system-name>,
Sensor values for <FRU Id>: <Sensor Value> <Sensor Value> <Sensor
Value> <Sensor Value> <Sensor Value> <Sensor Value> <Sensor Value>