HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
112 Error messages
BL-1012
Message
Probable Cause
Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch
operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this
number might not correspond to a user port number.
Recommended Action
Make sure to capture the console output during this process.
Check for a faulty cable, SFP, or device attached to the specified port.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot or power cycle the switch.
If the message persists, replace the blade or the (nonbladed) switch.
Severity
ERROR
BL-1013
Message
Probable Cause
Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch
operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this
number might not correspond to a user port number.
Recommended Action
Make sure to capture the console output during this process.
Check for a faulty cable, SFP, or device attached to the specified port.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot or power cycle the switch.
If the message persists, replace the blade.
Severity
ERROR
<timestamp>, [BL-1012], <sequence-number>,, ERROR, <system-name>,
bport <port number> port int. is disabled. status=0x<interrupt
status> Port <port number> will be re-enabled in 1 minute.
<timestamp>, [BL-1013], <sequence-number>,, ERROR, <system-name>,
bport <port number> port is faulted. status=0x<interrupt status>
Port <port number> will be re-enabled in 1 minute.