HP StorageWorks Fabric OS 5.X Command Reference Guide (AA-RVHVB-TE, September 2005)

Table Of Contents
Fabric OS 5.x command reference guide 747
Displays the current level of the voltage sensors on a system.
Synopsis
voltshow
Availability
admin
Description
Use this command to display information about a switch's voltage levels. The format of the display varies
according to the switch model, the number of voltages on the device, and the number of voltage sensors
present.
This command displays the following fields:
Operands
none
voltShow
FRU Type One of the following values: CHASSIS, FAN, I2C, Control,
CFlash, SW BLADE (switch), CP BLADE (control processor), or
UNKNOWN.
Number Slot or unit number, if applicable.
Voltage levels The measured voltage for these designated voltage levels: 1.2
or 1.8 volts (depending on the ASIC type), 2.5 volts, 3.3 volts,
5 volts, 12 volts, 48 volts, and 53 volts.
If a voltage level is above its programmed maximum, it has a
“+” appended; if it is below its programmed minimum, a “-” is
appended. Nonapplicable voltage levels are displayed as
“--.