HP StorageWorks Fabric OS 4.4.0F Release Notes (AA-RW89A-TE, October 2005)

Core Switch 2/64 and SAN Director 2/128 installation guide, part number: AA-RVUSC-TE32
Core Switch 2/64 and SAN Director 2/128 installation guide,
part number: AA-RVUSC-TE
This section provides information on last-minute additions or corrections to the
HP StorageWorks Core
Switch 2/64 and SAN Director 2/128 installation guide,
part number AA–RVUSC–TE.
On page 45, insert the following “Powering off the switch” section:
To power off the Core Switch 2/64:
1. Shut down both logical switches:
a. Enter the switchShutdown command to ensure a graceful shutdown of Switch 1, and
verify the command has completed and displayed the message “Cleaning up kernel
modules.....Done.
b. From the active CP card session, log into Switch 0 by entering the login command, logging
in as admin, then entering “0” to log into Switch 0.
c. Enter the switchShutdown command to ensure a graceful shutdown of Switch 0, and
verify the command has completed and displayed the message “Cleaning up kernel
modules.....Done.
Example:
SW1:admin> switchshutdown
Stopping all switch daemons...Done.
Powering off slot 7...Done.
Powering off slot 10...Done.
Checking all slots are powered off...Done.
Cleaning up kernel modules.....Done
SW1:admin>
SW1:admin> login
login: admin
Enter Switch Number to Login <0 or 1>: 0
password: xxxx
SW0:admin>
SW0:admin> switchshutdown
Stopping all switch daemons...Done.
Powering off slot 1...Done.
Powering off slot 4...Done.
Checking all slots are powered off...Done.
Cleaning up kernel modules.....Done
SW0:admin>