Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

Fabric OS Message Reference 3-7
Publication Number: 53-1000242-01
BL-1016
3
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the systemVerification command to determine if there is a hardware error.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
On the SilkWorm 12000, 24000, and 48000, replace the blade FRU.
On the SilkWorm 3900, replace the motherboard FRU.
On the SilkWorm 200E, 3016, 3250, 3850, or 4100, replace the switch.
Severity ERROR
BL-1016
Message
Probable
Cause
Indicates that the specified blade port has failed to get enabled.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the blade.
Severity CRITICAL
BL-1017
Message
Probable
Cause
Indicates that the slot has started initializing the ports.
Recommended
Action
No action is required.
Severity INFO
<timestamp>, [BL-1016], <sequence-number>, FFDC, CRITICAL, <system-
name>, Blade port <port number> in slot <slot number> failed to
enable.
<timestamp>, [BL-1017], <sequence-number>,, INFO, <system-name>,
Slot <slot number> Initializing...