Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)

3-4 Fabric OS Message Reference
Publication Number: 53-1000242-01
BL-1009
3
If the message persists, replace the blade.
Severity CRITICAL
BL-1009
Message
Probable
Cause
Indicates that the blade has failed to initialize the ASIC chips.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the blade.
Severity CRITICAL
BL-1010
Message
Probable
Cause
Indicates that a failover occurred while some hardware changes were being made on the previously
active CP (such as changing the domain ID).
Recommended
Action
No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.
Severity WAR NIN G
BL-1011
Message
<timestamp>, [BL-1009], <sequence-number>, FFDC, CRITICAL, <system-
name>, Blade in slot <slot number> timed out initializing the chips.
<timestamp>, [BL-1010], <sequence-number>,, WARNING, <system-name>,
Blade in slot <slot number> inconsistent with the hardware
settings.
<timestamp>, [BL-1011], <sequence-number>, FFDC, CRITICAL, <system-
name>, Busy with emb-port int. for chip <chip number> in minis
<minis number> on blade <slot number>, chip int. is disabled.
interrupt status=0x<interrupt status>