Brocade Fabric OS Message Reference Guide (53-1000242-01, November 2006)
Fabric OS Message Reference 58-41
Publication Number: 53-1000242-01
SEC-1167
58
SEC-1167
Message
Probable
Cause
Indicates that because another failover is already in progress, this failover attempt cannot proceed.
Recommended
Action
Verify that the security event was planned. If the security event was planned, retry FCS failover after
current failover has completed, if this switch should become primary FCS. If the security event was not
planned, take appropriate action as defined by your enterprise security policy.
Severity ERROR
SEC-1168
Message
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
Severity ERROR
SEC-1170
Message
Probable
Cause
Indicates that there has been a corruption during the distribution of the security database. This can only
occur when the primary FCS is distributing the security database to the other switches in the fabric and
local validation finds that there is an error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be
in the ready state. If a switch is in the error state, the database might not be correctly updated for that
specific switch.
<timestamp>, [SEC-1167], <sequence-number>,, ERROR, <system-name>,
Another FCS failover is in process. Command terminated.
<timestamp>, [SEC-1168], <sequence-number>,, ERROR, <system-name>,
Primary FCS failover is busy. Please retry later.
<timestamp>, [SEC-1170], <sequence-number>,, INFO, <system-name>,
This command must be executed on the Primary FCS switch, the first
reachable switch in the FCS list.