HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 403
ZONE-1007
Message
Probable Cause
Indicates that frame filter logic reported a failure during one of the IOCTL calls. The IOCTL call from which
the failure is reported is listed as part of the error message. This is usually a programming error when
adding CAM entries before the filter setup.
Recommended Action
There are two ways to avoid this problem.
• Avoid having too many hosts zoned with a set of target devices at a single port.
• Avoid having too many zones directed at a single port group on the switch.
Severity
INFO
ZONE-1008
Message
Probable Cause
Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a zone
group. The maximum number of CAM entries allowed depends on the ASIC.
Recommended Action
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that port.
Severity
WARNING
ZONE-1010
Message
Probable Cause
Indicates that there are duplicate entries in a zone object. A zone object member is specified twice in a
given zone object. This message occurs only when enabling a zone configuration.
Recommended Action
Check the members of the zone and delete the duplicate member.
<timestamp>, [ZONE-1007], <sequence-number>,, INFO, <system-name>,
Ioctl(<function>) in (<error message>) at port (<port number>)
returns code (<error string>) and reason string (<reason string>)
<timestamp>, [ZONE-1008], <sequence-number>,, WARNING,
<system-name>, WARNING - port <port number> Out of CAM entries
<timestamp>, [ZONE-1010], <sequence-number>,, WARNING,
<system-name>, WARNING - Duplicate entries in zone(<zone name>)
specification.