HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 321
Probable Cause
Indicates that the port member is invalid for one of the following reasons:
• The value is not a number.
• The value is too long. Valid numbers must be between one and three characters long.
• The value cannot be parsed due to invalid characters.
Recommended Action
Use valid syntax when entering port members.
Severity
ERROR
SEC-1042
Message
Probable Cause
Indicates that the specified area member is not within the minimum and maximum values.
Recommended Action
Use valid syntax when entering area numbers.
Severity
ERROR
SEC-1043
Message
Probable Cause
Indicates that the specified port is not within the minimum and maximum range.
Recommended Action
Use valid syntax when entering port ranges.
Severity
ERROR
SEC-1044
Message
<timestamp>, [SEC-1042], <sequence-number>,, ERROR, <system-name>,
Invalid area member <port member> in portlist (<Port list>). Out of
range (<Minimum value> - <Maximum value>).
<timestamp>, [SEC-1043], <sequence-number>,, ERROR, <system-name>,
Invalid port range <Minimum> - <Maximum>.
<timestamp>, [SEC-1044], <sequence-number>,, ERROR, <system-name>,
Duplicate member <member ID> in (<List>).