HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

270 Error messages
Probable Cause
Indicates that multiple fans have failed. This message is often preceded by a low fan speed message.
Recommended Action
For the SAN Switch 2/32 and SAN Switch 4/32, replace the fan FRU.
For the 4/8 SAN Switch, 4/16 SAN Switch, SAN Switch 2/8V and SAN Switch 2/16V, the entire switch
must be replaced, because these switches do not have FRUs.
Severity
WARNING
HIL-1401
Message
Probable Cause
Indicates that one fan FRU has been removed.
Recommended Action
Install the missing fan FRU.
Severity
WARNING
HIL-1402
Message
Probable Cause
Indicates that two fan FRUs have been removed.
Recommended Action
Install the missing fan FRUs immediately.
Severity
WARNING
HIL-1403
Message
Probable Cause
Indicates that all fan FRUs have been removed.
<timestamp>, [HIL-1401], <sequence-number>,, WARNING,
<system-name>, One fan FRU missing. Install fan FRU immediately.
<timestamp>, [HIL-1402], <sequence-number>,, WARNING,
<system-name>, Two fan FRUs missing. Install fan FRUs immediately.
<timestamp>, [HIL-1403], <sequence-number>,, WARNING,
<system-name>, All fan FRUs missing. Install fan FRUs immediately.