HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
Fabric OS 5.x diagnostics and system error messages reference guide 249
FW-1402
Message
Probable Cause
Indicates that the flash usage percentage has risen above the high boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to future
problems.
Recommended Action
You might have to remove some unwanted files to create some flash space. Run the saveCore command
to remove files from the kernel space.
Severity
WARNING
FW-1403
Message
Probable Cause
Indicates that the flash usage percentage has changed from a value outside of the acceptable range to a
value within the acceptable range. Flash increases and decreases slightly with normal operation of the
switch. Excessive permanent increases can lead to future problems.
Recommended Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
Severity
INFO
FW-1424
Message
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because of a policy violation. The
valid state values are HEALTHY, MARGINAL, or DOWN.
Recommended Action
Run the switchStatusShow command to determine the policy violation.
<timestamp>, [FW-1402], <sequence-number>,, WARNING, <system-name>,
<Label>, is above high boundary(High=<High value>, Low=<Low
value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1403], <sequence-number>,, INFO, <system-name>,
<Label>, is between high and low boundaries(High=<High value>,
Low=<Low value>). Current value is <Value> <Unit>.
<timestamp>, [FW-1424], <sequence-number>,, WARNING, <system-name>,
Switch status changed from <Previous state> to <Current state>.