HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)
122 Error messages
Try reseating the FRU. If the message persists, replace the FRU.
Severity
CRITICAL
EM-1010
Message
Probable Cause
Indicates that the environmental monitor received an unexpected power-down notification from the
specified FRU. However, the specified FRU still appears to be powered up after four seconds. This message
occurs only on the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
Try reseating the blade. If this fails to correct the error, replace the blade.
Severity
CRITICAL
EM-1011
Message
Probable Cause
Indicates that the environmental monitor (EM) received an unexpected power-down notification from the
FRU specified; however, after four seconds it cannot be determined if it has powered down or not. This
message occurs only on the Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director.
Recommended Action
Try reseating the blade. If this fails to correct the error, replace the blade.
Severity
CRITICAL
EM-1012
Message
<timestamp>, [EM-1010], <sequence-number>,, CRITICAL,
<system-name>, Received unexpected power down for <FRU Id> But <FRU
Id> still has power
<timestamp>, [EM-1011], <sequence-number>,, CRITICAL,
<system-name>, Received unexpected power down for <FRU Id>, but
cannot determine if it has power
<timestamp>, [EM-1012], <sequence-number>,, CRITICAL,
<system-name>, <FRU Id> failed <state> state transition, fru
faulted