Web Tools Administrator's Guide (53-1001772-01, June 2010)

196 Web Tools Administrator’s Guide
53-1001772-01
CHAP configuration
15
DRAFT: BROCADE CONFIDENTIAL
The CHAP module pane lists CHAP secrets in a table with the user name and chap secret in
encrypted format (*). You can add, delete, or modify CHAP entries. Each CHAP secret has:
User name maximum length of 64 characters
CHAP secret of maximum length of 32 characters
Creating a CHAP user
Use the following procedure to create a CHAP user.
1. Launch the iSCSI Target Gateway Admin module as described on page 188.
2. Select the CHAP tab.
3. Click Create.
4. Enter the CHAP user name.
Optional: To add more than one user at a time, click Add.
5. Enter a CHAP secret and click Apply.
Editing a CHAP secret
Use the following procedure to edit a CHAP secret.
1. Launch the iSCSI Target Gateway Admin module as described on page 188.
2. Select the CHAP tab.
3. Click Change CHAP Secret. You can edit the CHAP secret, but not the CHAP user name.
4. Fill in the fields in the dialog box to edit a CHAP secret.
Binding or removing CHAP users
Use the following procedure to bind or remove CHAP users.
1. Launch the iSCSI Target Gateway Admin module as described on page 188.
2. Select the CHAP tab.
3. Click Bind/Remove Chap(s).
4. Select a virtual target.
5. Enter a new CHAP user, if necessary.
6. Select the CHAP users and click Add or Remove to move them into the appropriate list
(unassociated or associated CHAP users).
7. Cl ick Apply.