Fabric OS 5.3.1a fixes
Table 4 lists defects closed in the Fabric OS 5.3.1a firmware release.
Table 4 Fabric OS 5.3.1a closed defects
SolutionClosed defect summary
Fixed in Fabric OS 5.3.1a
F_Port link initialization failure caused by
the switch not responding to NOS with OLS
(continues to send idles).
Fixed in Fabric OS 5.3.1a
If your switch is not upgraded to 5.3.1a, the workaround is to
issue firmwaredownload with the -sf option:
firmwaredownload —sf
nl
Use default answers so that firmwaredownload does not re-
boot after download, then perform the following steps:
nl
mount -oremount,ro /mntumount /mnt
nl
hareboot
When downgrading from 6.0.0x to Fabric
OS 5.3.0c, then 5.2.1b, then 5.0.5a, the
switch can get into an endless reboot caus-
ing file system errors to be reported.
Fixed in Fabric OS 5.3.1a
FR4-18i blade is faulted during operation
with internal FCIP-5031 raslog and external
EM-1034 raslog.
Fixed in Fabric OS 5.3.1a
The zoneadmin feature in Web Tools does
not display the new ports after adding a
new blade.
Fixed in Fabric OS 5.3.1a
Only 1 FL port FLOGI is successful and
second FL port FLOGI is disabled in a time
interval. Even though FL port will be re-en-
abled after the short time interval, 3rd party
failover application may fail.
Fixed in Fabric OS 5.3.1a
When the proxy device projected to the
backbone had a translate domain of greater
than 0x20, router is not translating the ACC
for a REC properly. Customer observes
traffic interrupted and tape device fail.
Fixed in Fabric OS 5.3.1a
When there is an application request GPPN
on a device connected to multiple switches,
customer might see continuous rtwr mes-
sage on a pair of switches and directed at
each other from msd:
nl
[RTWR-1003],,, INFO, , msd0:
RTWR retry 48 to domain 152,
iu_data 1000000 RTWR Maxretries
exhausted: 0x30, 0x8, 0x65, 0x0,
0x41d on multipath switches.
nl
Potential for switch panic when memory is
exhausted.
HP StorageWorks Fabric OS 5.3.2 release notes 19