496 Fabric OS Administrator’s Guide
53-1002148-02
FC-FC Routing and Virtual Fabrics
23
Phantom Port WWNs
Max proxy devices
Max NR_Ports
The following example shows the use of the fcrResourceShow command to display physical port
(EX_Port) resources.
switch:admin> fcrresourceshow
Daemon Limits:
Max Allowed Currently Used
-------------------------------
LSAN Zones: 3000 28
LSAN Devices: 10000 51
Proxy Device Slots: 10000 20
WWN Pool Size Allocated
---------------------------------
Phantom Node WWN: 8192 5413
Phantom Port WWN: 32768 16121
Port Limits:
Max proxy devices: 2000
Max NR_Ports: 1000
Currently Used(column 1: proxy, column 2: NR_Ports):
0 | 0 34
1 | 3 34
4 | 0 0
5 | 0 0
6 | 0 0
7 | 0 0
8 | 6 34
9 | 6 34
10 | 6 34
11 | 6 34
12 | 6 34
13 | 6 34
14 | 6 34
15 | 6 34
16 | 8 34
17 | 8 34
18 | 8 34
19 | 8 34
20 | 8 34
21 | 8 34
22 | 8 34
23 | 8 34
FC-FC Routing and Virtual Fabrics
If Virtual Fabrics is not enabled, FC-FC routing behavior is unchanged. If Virtual Fabrics is enabled,
then in the FC-FC routing context, a base switch is like a backbone switch and a base fabric is like a